{"product_id":"fbt-dlm-26-digital-speaker-management-system","title":"FBT – DLM-26 DIGITAL SPEAKER MANAGEMENT SYSTEM","description":"\u003ch3\u003eDESCRIPTION:\u003c\/h3\u003e\n\u003cdiv id=\"tab-description\" class=\"custom-details\"\u003e\n\u003cp\u003eThe DLM26 is a DSP based  2 input x 6 output Digital Loudspeaker management processor, ideally suited for fixed installations and live events.\u003cstrong\u003e \u003c\/strong\u003eIt combines the functions of a multitude of conventional products in a compact 1U unit with extensive PC remote control capabilities.\u003c\/p\u003e\n\u003cp\u003eFeatures Superb audio quality with premium hi-end AKM5392 24bit A\/D converters and AKM 4396 24bit D\/A converters, carefully optimized double precision signal processing coupled with 24bit conversion ensure a dynamic range \u0026gt;110db\u003c\/p\u003e\n\u003cp\u003eThe unit can work in STANDARD MODE or in DCL MODE. The first mode permit to configure the crossover in 2×2 way + SUB, 2×3 way or 6way, the input L, R, L+R are freely assignable to each output.\u003c\/p\u003e\n\u003cp\u003eIn DCL mode the unit can be configured in 3ch DCL, 2ch DCL + 2ch standard, 1ch DCL + 4ch standard. DCL mode mean double compressor limiter, each DCL channel have a double band limiter and compressor with assignable LO\/HI split frequency. This is an exclusive feature in digital processor and it’s very useful to protect two way passive filters with no passive attenuation in the crossover between LF woofer and HF driver. With DCL mode is possible to set two different threshold of protection for woofer and driver with the split frequency corresponding to the passive crossover frequency.\u003c\/p\u003e\n\u003cp\u003eEach input has 5  fully configurable filters, a delay of 288.66ms max in step of 6.8us, gain.\u003c\/p\u003e\n\u003cp\u003eEach output has 4 fully configurable filters, a delay of 288.66ms max in step of 6.8us, gain, phase, LO-pass\/Hi-pass crossover from 6 to 24db\/Oct with standard or custom Q, RMS compressor with soft knee and peak limiter.\u003c\/p\u003e\n\u003cp\u003eThe 2 input levels are displayed by rows of 6 level LED + 1 clip led, the 6 output levels are displayed by rows of 5 level LED + 1 clip led + 1 Limiter led. The unit has 2 analog inputs, a stereo digital SPDIF input, and 6 analog outputs. Linking functions between inputs and linking functions between outputs are available.\u003c\/p\u003e\n\u003cp\u003eA function is allowing to have ramps closing the output level on parameter changes, when the unit is used as installation unit; this function can be excluded when the unit is used live and it is necessary to perform small changes to the set parameter…on the fly.\u003c\/p\u003e\n\u003cp\u003eThe Pc SW for the remote control via RS485 or USB is allowing to connect in net up to 32 units and is allowing to control full parameters of the processor, to show the phase of the filter setting and to adjust graphically the RMS compressor and the Peak limiter. The comprehensive standard specification also include up to 64 memories with security lockout and two password level settings.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"tab-specifications_tab\" class=\"custom-details\"\u003e\n\u003ch3\u003eSPECIFICATIONS:\u003c\/h3\u003e\n\u003cul class=\"specifications\"\u003e\n\u003cli\u003e\n\u003cspan class=\"left\"\u003e\u003cstrong\u003eAnalog Input Signal:\u003c\/strong\u003e\u003c\/span\u003e \u003cspan class=\"right\"\u003e ChA\/ChB, Bal. Female XLR\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"left\"\u003e\u003cstrong\u003e Maximum Input Level:\u003c\/strong\u003e\u003c\/span\u003e \u003cspan class=\"right\"\u003e +20dBu\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"left\"\u003e\u003cstrong\u003e Analog Output Signal:\u003c\/strong\u003e\u003c\/span\u003e \u003cspan class=\"right\"\u003e Ch1\/Ch2\/Ch3\/Ch4\/Ch5\/Ch6 Bal. Male XLR\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"left\"\u003e\u003cstrong\u003e Maximum Output Level:\u003c\/strong\u003e\u003c\/span\u003e \u003cspan class=\"right\"\u003e +20dBu\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"left\"\u003e\u003cstrong\u003e Digital Processing (DSP):\u003c\/strong\u003e\u003c\/span\u003e \u003cspan class=\"right\"\u003e SAM3716, 24bits (data) x 96 bits (coeff.)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"left\"\u003e\u003cstrong\u003e A\/D Converters:\u003c\/strong\u003e\u003c\/span\u003e \u003cspan class=\"right\"\u003e AKM5392, 24bits\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"left\"\u003e\u003cstrong\u003e D\/A Converters:\u003c\/strong\u003e\u003c\/span\u003e \u003cspan class=\"right\"\u003e AKM4396, 24bits\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"left\"\u003e\u003cstrong\u003e Sampling Frequency:\u003c\/strong\u003e\u003c\/span\u003e \u003cspan class=\"right\"\u003e 48kHz\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"left\"\u003e\u003cstrong\u003e S\/PDIF Stereo Digital Input:\u003c\/strong\u003e\u003c\/span\u003e \u003cspan class=\"right\"\u003e 32kHz, 44.1kHz and 48kHz Sources Accepted\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"left\"\u003e\u003cstrong\u003e S\/N:\u003c\/strong\u003e\u003c\/span\u003e \u003cspan class=\"right\"\u003e 110dBA\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"left\"\u003e\u003cstrong\u003e THD+N:\u003c\/strong\u003e\u003c\/span\u003e \u003cspan class=\"right\"\u003e 0.005%\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"left\"\u003e\u003cstrong\u003e Frequency Response (Bypass):\u003c\/strong\u003e\u003c\/span\u003e \u003cspan class=\"right\"\u003e 20Hz – 20kHz (+- 1 dB)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"left\"\u003e\u003cstrong\u003e Power Supply:\u003c\/strong\u003e\u003c\/span\u003e \u003cspan class=\"right\"\u003e Switching Power Supply\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"left\"\u003e\u003cstrong\u003e Remote Control:\u003c\/strong\u003e\u003c\/span\u003e \u003cspan class=\"right\"\u003e USB, RS485\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"tab-bullets_tab\" class=\"custom-details\"\u003e\n\u003ch3\u003eFEATURES:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHi-pass\/Lo-pass\/Shelving custom Q second order filters\u003c\/li\u003e\n\u003cli\u003eRMS compressor and PEAK limiter on each output channel with time constant and algorithm optimized for speaker thermal and mechanical protection while maximizing the output with no audible distortion\u003c\/li\u003e\n\u003cli\u003eInput channel L, R or L + R freely assignable to each output channel\u003c\/li\u003e\n\u003cli\u003eDouble Compressor Limiter Mode (DCL) with two band RMS compressor and Peak limiter with adjustable HP \/ LP split frequency and separate parameter adj. This is an exclusive and very useful feature in general purpose digital processors\u003c\/li\u003e\n\u003cli\u003eALL PASS first and second order filters useful for Cardioid SUB configurations, very precise phase crossover alignment, special pattern control array, alignment between different speakers and systems\u003c\/li\u003e\n\u003cli\u003eEach output has 4 fully configurable filters, a delay of 288.66ms max in step of 6.8us, gain, phase, LO-pass\/Hi-pass crossover from 6 to 24db\/Oct with standard or custom Q, RMS compressor with soft knee and peak limiter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Sound Select ZA","offers":[{"title":"Default Title","offer_id":46529311375526,"sku":"343.250FB","price":20195.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0691\/1646\/1222\/files\/fbt_dlm-26_digital_speaker_management.png?v=1764693352","url":"https:\/\/soundselect.co.za\/fr\/products\/fbt-dlm-26-digital-speaker-management-system","provider":"Sound Select ZA","version":"1.0","type":"link"}